Sampling skids

Representative samples of crude and other liquids, taken automatically or by hand.

Sampling skid
Sampling skidSkid-mounted sampling point: isolation valves, sample probe, sampler and receiver on one frame, built and tested in our workshops.
At a glance

A sample is only worth what it represents. We condition the stream first, then draw the sample.

  • Automatic flow-proportional, time-proportional or manual sampling
  • Static or motorized mixer, or circulation loop, for fluid conditioning
  • Composite receivers with mixing and level indication
  • Pressurized floating-piston cylinders for volatile liquids
Concept

What the skid looks like

Illustrative rendering of the configuration; real photos of our builds are on the projects page.

Illustration: Sampling skid
Illustration: Sampling skidAutomatic sampler with sample receivers, conditioning and pump on one frame.
Delivered
  • Automatic sampler integrated in the LACT unit for Petronas, MyanmarPetronas
See LACT units →
Learn more

How it works, configurations and standards

Open the sections you need. Everything stays on the page for reference and print.

01

How it works

Process diagram and step-by-step timeline

Water and solids settle toward the pipe wall. A static or motorized mixer blends the stream before the probe, and the probe draws from the center of the pipe, so the composite sample matches what actually flows.

The automatic sampler takes small, equal portions in proportion to flow, driven by a pulse from your meter or flow computer. Manual sampling points give spot checks and a backup. The controller counts pulses, commands the sampler, raises alarms and reports status to your SCADA.

In the order the fluid passes through it. Select a step, use the arrows, or let it play.

static or motorized mixerSAMPLERautomaticsurplusreturns to lineRECEIVERMComposite samplefor the laboratoryspot sampleFTFlow signalfrom your meter1Inlet2Conditioning3Probe4Sampler5Sample receiver6Manual sampling7OutletCONTROL AND RECORDSSampler controllerpulse count, alarms, statusto yourSCADA

Typical schematic configuration, shown for reference only. The final design, equipment, instrumentation and applicable codes depend on the client's process conditions, specification and project requirements, and are defined during engineering.

Swipe sideways to see the whole diagram.

1 / 8
Step 1 of 8

Inlet and isolation

The stream enters through an isolation valve, upstream of the sampling point.

Step 2 of 8

Fluid conditioning

A static or motorized mixer blends oil, water and solids so the stream is uniform where the sample is taken.

Step 3 of 8

Sample probe

Takes the sample from the middle of the pipe, not from the wall, where water and solids settle toward the bottom of the pipe.

Step 4 of 8

Automatic sampler

Takes small, equal portions in proportion to flow, using a pulse from your meter or flow computer.

Step 5 of 8

Sample receiver

Collects the portions into one composite sample, with mixing, ready to take to the laboratory.

Step 6 of 8

Manual sampling point

Valves and a closed container to take spot samples by hand, as a check or as a backup.

Step 7 of 8

Return and outlet

The surplus sample returns to the line, so no product is lost. The product continues to the outlet.

Control and records

Controller

Counts flow pulses, commands the sampler, raises alarms and sends status to your SCADA.

02

Typical configurations and options

What goes on the skid and what can change

Sampling methods and fluid conditioning

We select the method and the mixer for your fluid, flow range and contract standard.

Automatic, flow-proportional

Follows the flow, so the composite sample represents the whole batch or period. No operator needed. Needs a flow signal from the meter; sampler and receiver are sized for the flow and the batch.

Manual (spot)

Simple and low in cost. Useful as a check on the automatic sampler or as a backup. Depends on the operator and the moment, so it does not represent a flow that changes over time.

Pressurized cylinder

Closed, floating-piston sample that keeps light components in the sample, for volatile liquids that must not lose vapor. Needs a pressure-rated sample connection.

Static mixer

Fixed elements in the pipe blend oil and water with no moving parts and no power. Works best within a flow range and adds pressure drop.

Motorized mixer

Powered mixing that works also at low flow and can be tuned to the fluid. Needs power and maintenance.

Configuration options

  • Sampling modeAutomatic proportional, manual, or both on the same skid
  • Sampler drivePneumatic or electric, selected for the site utilities and area
  • Sample triggerFlow pulse from your meter or flow computer, or time-based
  • Fluid conditioningStatic mixer, motorized mixer or circulation loop
  • Sample conditioningWhen required, the sample is conditioned before analysis: temperature reduced with a heat exchanger and pressure with a regulator valve. Drains are provided whether the fluid is recycled or discharged, and temperature and pressure sensors and safety valves give monitoring and protection. The sample can be analyzed on the spot or taken to the laboratory
  • Sample probeSingle or multiple probes, sized for the line and the flow
  • Sample receiversOne or several composite receivers, with mixing and level indication
  • Pressurized samplingFloating-piston cylinders for volatile liquids, as required
  • ControlSampler controller or PLC; alarms; serial and Ethernet to your SCADA
  • InstrumentationPressure and temperature gauges, flow and level switches
  • IntegrationStand-alone skid, or integrated with a LACT or metering skid
  • Area classificationInstruments, panels and wiring selected for the classified area
  • MaterialsCarbon steel or stainless steel; NACE materials for sour service
  • ComponentsWe integrate Swagelok, Yokogawa, Magnetrol and Thermo Scientific, and consider your preference
03

Standards and documentation

Design references and the documents we deliver

Designed to ASTM, ASME, ISO and API standards. The applicable codes are agreed per project.

Typical references

  • API MPMS Ch. 8.1Manual sampling of petroleum and petroleum products
  • API MPMS Ch. 8.2Automatic sampling of liquid petroleum and products
  • API MPMS Ch. 8.3Mixing and handling of liquid samples
  • API MPMS Ch. 10Sediment and water
  • ISO 3170 · 3171Manual and automatic sampling of petroleum liquids
  • ASTM D4057 · D4177Practices for manual and automatic sampling

Typical documentation package

  • P&ID
  • General arrangement
  • Instrument datasheets
  • Calculations
  • FAT procedure and report
  • Operation and maintenance manual

Factory acceptance test (FAT) in our workshops and site acceptance test (SAT) at the installation site.

Brands

Typical brands on this skid

Brands we represent, integrated alongside your preference.

Yokogawa
Westlock
Flowserve

See all brands →

From specification to start-up

One team, from engineering to the factory test

  1. Step 1

    Engineering

    Process, mechanical and instrumentation design from your specification.

  2. Step 2

    Fabrication

    Built and assembled in our workshops to the agreed codes.

  3. Step 3

    Factory test (FAT)

    Loop-by-loop checks, valve stroking and control verification, with your witnesses if you wish.

  4. Step 4

    Start-up

    Documentation, delivery and remote support.

Need one built for your process?

Send us fluid, flow, pressure and temperature, or just your idea. An engineer returns a proposed configuration.