Hydraulic power units
Stored hydraulic energy to actuate valves, with solar or battery power and remote control as options.

Stored hydraulic energy to move your valves.
- Energy stored in accumulators
- Solar or battery option
- Remote control available
- Built in our workshops
Hydraulic power units in our workshop
Real projects, photographed in our workshops and at site. Ask us for references in your application.


How it works, configurations and standards
Open the sections you need. Everything stays on the page for reference and print.
01How it works
Process diagram and step-by-step timeline
A hydraulic power unit stores energy in accumulators and releases it to actuate valves, even when the main supply is not available.
Solar or battery options and remote control are available for remote locations.
These are custom-built units that convert electrical or pneumatic energy into hydraulic energy to operate actuators. Autonomy is a key design factor: the energy is stored in accumulators and used to actuate valves in remote locations.
In the order the fluid passes through it. Select a step, use the arrows, or let it play.
Typical schematic configuration, shown for reference only. The final design, equipment, instrumentation and applicable codes depend on the client's process conditions, specification and project requirements, and are defined during engineering.
Swipe sideways to see the whole diagram.
Reservoir
Holds the hydraulic fluid, with breather and level indication. Sized for the volume the system and the actuators need.
Pumps
An electric motor-driven pump charges the system. A hand pump gives a backup way to build pressure with no power.
Protection
Check valves hold the pressure. A relief valve protects the circuit. A pressure switch starts and stops the pump.
Accumulators
Accumulators store the hydraulic energy, charged with nitrogen. They deliver fluid fast, even with the pump off.
Control manifold
Solenoid valves direct the stored fluid to the actuator on command, locally or from the control room.
Valve actuator
A hydraulic cylinder moves the valve. A spring-return actuator can drive the valve to its safe position, as configured.
Solar, battery or mains
A solar panel charges the battery through a charge controller. Mains supply is also possible where available.
Remote control
An RTU gives local or remote open/close commands and reports pressure and valve status to your SCADA.
When the supply is lost
The accumulators still hold energy for valve strokes, so the valve can be operated without main power.
02Typical configurations and options
What goes on the skid and what can change
- Valves servedOne or several valves from one unit; ball, gate, plug or other types
- Actuator typeSingle-acting spring return, or double-acting; part-turn or linear
- Stored energyCylinders sized for the number of strokes required without power
- Accumulator typeBladder or piston, with nitrogen pre-charge
- Pump and driveElectric motor-driven pump; hand pump as backup
- Hydraulic fluidMineral or fire-resistant fluid; selected for the ambient temperature range
- Power optionMains supply, solar panel with battery, or battery only
- ControlLocal push buttons, solenoid valves and pressure switch; optional PLC or RTU
- Remote controlOpen/close commands and status over radio, cellular or satellite to your SCADA
- Safety functionEmergency shutdown input; fail-safe position on loss of signal, as configured
- InstrumentationPressure gauges and transmitters, level indication, position feedback
- Enclosure and areaWeatherproof cabinet; components selected for the classified area
- Materials and tubingCarbon or stainless steel; stainless tubing for corrosive or marine sites
- BrandsWe integrate valves and actuators from our represented brands, or your preference
03Standards and documentation
Design references and the documents we deliver
Designed to ASTM, ASME, ISO and API standards. The applicable codes are agreed per project.
Typical references
- ISO 4413Hydraulic fluid power: safety rules for systems
- ISO 4406Coding of fluid cleanliness (particle counts)
- ASME VIII Div. 1Pressure vessels, such as accumulators and cylinders
- ASME B31.3Process piping and tubing
- ISO 5211Mounting flanges for part-turn valve actuators
- IEC 61511Functional safety, where a safety function applies
Typical documentation package
- P&ID and hydraulic schematic
- General arrangement
- Equipment and instrument datasheets
- Accumulator and stroke calculations
- Electrical schematics and power budget
- FAT procedure and report
- Fluid cleanliness record
- Operation and maintenance manual
Factory acceptance test (FAT) in our workshops and site acceptance test (SAT) at the installation site.
Typical brands on this skid
Brands we represent, integrated alongside your preference.




One team, from engineering to the factory test
- Step 1
Engineering
Process, mechanical and instrumentation design from your specification.
- Step 2
Fabrication
Built and assembled in our workshops to the agreed codes.
- Step 3
Factory test (FAT)
Loop-by-loop checks, valve stroking and control verification, with your witnesses if you wish.
- Step 4
Start-up
Documentation, delivery and remote support.