Controval
Power and utilities

Hydraulic power units

Stored hydraulic energy to actuate valves, with solar or battery power and remote control as options.

Hydraulic power unit: accumulator racks in the workshop
Hydraulic power unit: accumulator racks in the workshopNitrogen-charged accumulator banks on structural frames, with hydraulic actuator cylinders ready for assembly.
At a glance

Stored hydraulic energy to move your valves.

  • Energy stored in accumulators
  • Solar or battery option
  • Remote control available
  • Built in our workshops
Our work

Hydraulic power units in our workshop

Real projects, photographed in our workshops and at site. Ask us for references in your application.

Accumulator racks in the workshop
Accumulator racks in the workshopAccumulator racks that store the hydraulic energy used to stroke the valves.
Electro-hydraulic power unit with control cabinet
Electro-hydraulic power unit with control cabinetReservoir, motor-driven pump, manifold and control cabinet on a compact frame.
Learn more

How it works, configurations and standards

Open the sections you need. Everything stays on the page for reference and print.

01

How it works

Process diagram and step-by-step timeline

A hydraulic power unit stores energy in accumulators and releases it to actuate valves, even when the main supply is not available.

Solar or battery options and remote control are available for remote locations.

These are custom-built units that convert electrical or pneumatic energy into hydraulic energy to operate actuators. Autonomy is a key design factor: the energy is stored in accumulators and used to actuate valves in remote locations.

In the order the fluid passes through it. Select a step, use the arrows, or let it play.

hydraulic fluidMhand pump (backup)reliefPSN2N2N2PGvalve on your pipelinespring returnto reservoir1Reservoir2Pumps3Protection4Accumulators5Control manifold6Valve actuatorPOWER AND CONTROLsolar panel (option)Charge controllersolar or mainsBatterystores powerPower and control panelstarts the pump, drives the solenoidsRTU / remote controlcommand and statusto your SCADAor control room78

Typical schematic configuration, shown for reference only. The final design, equipment, instrumentation and applicable codes depend on the client's process conditions, specification and project requirements, and are defined during engineering.

Swipe sideways to see the whole diagram.

1 / 9
Step 1 of 9

Reservoir

Holds the hydraulic fluid, with breather and level indication. Sized for the volume the system and the actuators need.

Step 2 of 9

Pumps

An electric motor-driven pump charges the system. A hand pump gives a backup way to build pressure with no power.

Step 3 of 9

Protection

Check valves hold the pressure. A relief valve protects the circuit. A pressure switch starts and stops the pump.

Step 4 of 9

Accumulators

Accumulators store the hydraulic energy, charged with nitrogen. They deliver fluid fast, even with the pump off.

Step 5 of 9

Control manifold

Solenoid valves direct the stored fluid to the actuator on command, locally or from the control room.

Step 6 of 9

Valve actuator

A hydraulic cylinder moves the valve. A spring-return actuator can drive the valve to its safe position, as configured.

Step 7 of 9

Solar, battery or mains

A solar panel charges the battery through a charge controller. Mains supply is also possible where available.

Step 8 of 9

Remote control

An RTU gives local or remote open/close commands and reports pressure and valve status to your SCADA.

Control and records

When the supply is lost

The accumulators still hold energy for valve strokes, so the valve can be operated without main power.

02

Typical configurations and options

What goes on the skid and what can change
  • Valves servedOne or several valves from one unit; ball, gate, plug or other types
  • Actuator typeSingle-acting spring return, or double-acting; part-turn or linear
  • Stored energyCylinders sized for the number of strokes required without power
  • Accumulator typeBladder or piston, with nitrogen pre-charge
  • Pump and driveElectric motor-driven pump; hand pump as backup
  • Hydraulic fluidMineral or fire-resistant fluid; selected for the ambient temperature range
  • Power optionMains supply, solar panel with battery, or battery only
  • ControlLocal push buttons, solenoid valves and pressure switch; optional PLC or RTU
  • Remote controlOpen/close commands and status over radio, cellular or satellite to your SCADA
  • Safety functionEmergency shutdown input; fail-safe position on loss of signal, as configured
  • InstrumentationPressure gauges and transmitters, level indication, position feedback
  • Enclosure and areaWeatherproof cabinet; components selected for the classified area
  • Materials and tubingCarbon or stainless steel; stainless tubing for corrosive or marine sites
  • BrandsWe integrate valves and actuators from our represented brands, or your preference
03

Standards and documentation

Design references and the documents we deliver

Designed to ASTM, ASME, ISO and API standards. The applicable codes are agreed per project.

Typical references

  • ISO 4413Hydraulic fluid power: safety rules for systems
  • ISO 4406Coding of fluid cleanliness (particle counts)
  • ASME VIII Div. 1Pressure vessels, such as accumulators and cylinders
  • ASME B31.3Process piping and tubing
  • ISO 5211Mounting flanges for part-turn valve actuators
  • IEC 61511Functional safety, where a safety function applies

Typical documentation package

  • P&ID and hydraulic schematic
  • General arrangement
  • Equipment and instrument datasheets
  • Accumulator and stroke calculations
  • Electrical schematics and power budget
  • FAT procedure and report
  • Fluid cleanliness record
  • Operation and maintenance manual

Factory acceptance test (FAT) in our workshops and site acceptance test (SAT) at the installation site.

Brands

Typical brands on this skid

Brands we represent, integrated alongside your preference.

Parker
Flowserve
Westlock
Yokogawa

See all brands →

From specification to start-up

One team, from engineering to the factory test

  1. Step 1

    Engineering

    Process, mechanical and instrumentation design from your specification.

  2. Step 2

    Fabrication

    Built and assembled in our workshops to the agreed codes.

  3. Step 3

    Factory test (FAT)

    Loop-by-loop checks, valve stroking and control verification, with your witnesses if you wish.

  4. Step 4

    Start-up

    Documentation, delivery and remote support.

Need one built for your process?

Send us fluid, flow, pressure and temperature, or just your idea. An engineer returns a proposed configuration.

Get a quoteSkids