Controval
Metering and transfer

LACT units

Measures the volume and quality of crude at the custody transfer point. Configured to your specification and the regulations of each country.

LACT unit, Chevron Petroindependencia
LACT unit, Chevron PetroindependenciaCustody transfer metering unit installed at site: meter runs, valves and instrumentation on a common skid.
At a glance

Volume and quality, measured where the crude changes hands.

  • Filtration, air elimination, BS&W monitoring, metering, automatic sampling, flow computer and transfer ticket
  • Coriolis, magnetic, turbine, ultrasonic or positive displacement metering
  • One or several metering runs, with prover or master meter connection
  • Configured to your specification and the regulations of each country
Our work

LACT and metering skids we have built

Real projects, photographed in our workshops and at site. Ask us for references in your application.

LACT unit for Petronas aboard a vesselMetering lines of the Petronas LACT unitPiping and pumps of the Petronas LACT unit
Featured project

LACT unit for Petronas, Myanmar

3Metering lines
4,420BPH per line
  • Installed aboard a vessel
  • Coriolis meter, density and water-cut analyzer, flow computers, automatic sampler and HMI
  • Engineering, procurement, fabrication, FAT/SAT and remote support
  • Client: ENRA SPMT, Petronas Myanmar Operations. LACT unit for condensate storage, offloading facilities and service
  • Installation and mechanical, electrical and instrumentation assembly on the vessel; engineering deliverables include 3D model, piping stress analysis, hydraulic simulation, isometrics, structural design and lifting operation plan; logistics methodology and project monitoring and control
Crude quality and flow metering skid, Merey 20, PDVSA
Crude quality and flow metering skid, Merey 20, PDVSAMetering runs with gate valves, flow meters and quality instruments on a skid with access platform, installed at site.
Quality and flow metering skid, Arecuna 4, PDVSA
Quality and flow metering skid, Arecuna 4, PDVSASkid-mounted metering and quality measurement for crude, piped into the station.
Arecuna 4 metering skid under assembly in our workshop, PDVSA
Arecuna 4 metering skid under assembly in our workshop, PDVSAMeter run piping and valves being assembled before factory acceptance testing.
Delivered
  • LACT unit, three metering lines, MyanmarPetronas
  • Two LACT units: diluent and crudeChevron, Petroindependencia
  • Quality and flow metering skids: Merey 15, 18 and 20, Oficina 16, Arecuna 4, Bared 5PDVSA
See all projects →
Learn more

How it works, configurations and standards

Open the sections you need. Everything stays on the page for reference and print.

01

How it works

Process diagram and step-by-step timeline

A LACT unit measures the volume and quality of crude at the custody transfer point. Filtration, air elimination, BS&W monitoring, metering, automatic sampling, flow computer and transfer ticket, on one skid.

The metering technology is selected per project: Coriolis, magnetic, turbine, ultrasonic or positive displacement. One or several metering runs, with a prover or master meter connection.

Instruments, equipment and mechanical and electrical elements are integrated on modular skids for efficient transport, installation and commissioning at site, so that all fiscal entities and users involved work from one consistent package.

In the order the fluid passes through it. Select a step, use the arrows, or let it play.

BS&WSAMPLERautoRECEIVERsample receiver with mixingMETERMETERrun 1run nProver / master meterconnection1Inlet2Strainer3Air eliminator4BS&W monitor5Sampling6Metering runs7Back-pressure control8OutletCONTROL AND RECORDSFlow computernet volume, totals, alarmsTransfer ticket printerrecord of the transferHMI / control paneloperation and statusto yourSCADA

Typical schematic configuration, shown for reference only. The final design, equipment, instrumentation and applicable codes depend on the client's process conditions, specification and project requirements, and are defined during engineering.

Swipe sideways to see the whole diagram.

1 / 9
Step 1 of 9

Inlet and isolation

Crude from the lease or tank battery enters through an isolation valve. A supply pump is added when line pressure is not enough.

Step 2 of 9

Strainer

Retains solids and debris that could damage or distort the meter. Differential pressure can be monitored to plan cleaning.

Step 3 of 9

Air / gas eliminator

Separates and vents entrained gas so that only liquid reaches the meter and the volume is not overstated.

Step 4 of 9

BS&W monitor

An in-line analyzer measures water content (water cut) continuously. Off-specification crude can raise an alarm or be diverted, as configured.

Step 5 of 9

Sampling

A probe takes a flow-proportional sample from a well-mixed stream, downstream of a static mixer or other mixing device, into a sealed receiver for laboratory analysis.

Step 6 of 9

Metering and proving

One or more metering runs measure the flow. A prover or master meter connection allows the meters to be proved in place.

Step 7 of 9

Back-pressure control

Holds the pressure above the fluid's vapor pressure so it stays in a single phase through the meter. Where needed, flow control keeps flow within the meter range.

Step 8 of 9

Outlet

Measured crude leaves to the pipeline, tank or vessel through the outlet isolation valve.

Control and records

Flow computer, HMI and ticket

The flow computer calculates net volume, the HMI shows status and alarms, the printer issues the transfer ticket. Data goes to your SCADA.

02

Typical configurations and options

What goes on the skid and what can change

Metering technology

We select the principle for your fluid and the accuracy required.

  • Coriolis
  • Magnetic
  • Turbine
  • Ultrasonic
  • Positive displacement

Configuration options

  • Metering runsOne or several runs; duty / standby or parallel operation
  • Run sizeSized for the flow range and the allowed pressure drop
  • Meter technologyCoriolis, magnetic, turbine, ultrasonic or positive displacement
  • ProvingCompact, bidirectional or master meter; or provision for a future connection
  • SamplingAutomatic proportional or manual; composite sample receiver; sample mixing
  • BS&W / water cutIn-line water-cut monitoring, with alarm or diversion as required
  • Flow computer and SCADAFlow computer; serial and Ethernet communications to your SCADA
  • Back-pressure controlControl valve or back-pressure regulator
  • Strainer and air eliminatorSized and rated to the line and the fluid
  • Transfer ticketTransfer ticket and batch report printing
  • Area classificationInstruments, panels and wiring selected for the classified area
  • MaterialsCarbon steel or stainless steel; NACE materials for sour service
  • MountingSkid-mounted, or trailer or vessel mounting
  • Instrument brandsWe integrate Yokogawa, Flowserve, KECO, Magnetrol, Flexim, Swagelok and Thermo Scientific, and consider your preference

Brands we integrate

yokogawa
magnetrol
swagelok
flowserve
thermo
flexim

See all brands →

03

Standards and documentation

Design references and the documents we deliver

Designed to ASTM, ASME, ISO and API standards. The applicable codes are agreed per project.

Typical references

  • API MPMS Ch. 4Proving systems
  • API MPMS Ch. 5Metering
  • API MPMS Ch. 8Sampling
  • API MPMS Ch. 10Sediment and water
  • API MPMS Ch. 6.1Lease automatic custody transfer (LACT) systems
  • API MPMS Ch. 11.1Volume correction factors for temperature and pressure
  • API MPMS Ch. 12Calculation of petroleum quantities
  • API MPMS Ch. 21.2Electronic liquid volume measurement

Typical documentation package

  • P&ID
  • General arrangement
  • Instrument datasheets
  • Calculations
  • FAT procedure and report
  • Operation and maintenance manual

Factory acceptance test (FAT) in our workshops and site acceptance test (SAT) at the installation site.

Brands

Typical brands on this skid

Brands we represent, integrated alongside your preference.

Yokogawa
Magnetrol
Flowserve
Flexim
KECO

See all brands →

From specification to start-up

One team, from engineering to the factory test

  1. Step 1

    Engineering

    Process, mechanical and instrumentation design from your specification.

  2. Step 2

    Fabrication

    Built and assembled in our workshops to the agreed codes.

  3. Step 3

    Factory test (FAT)

    Loop-by-loop checks, valve stroking and control verification, with your witnesses if you wish.

  4. Step 4

    Start-up

    Documentation, delivery and remote support.

Need one built for your process?

Send us fluid, flow, pressure and temperature, or just your idea. An engineer returns a proposed configuration.

Get a quoteSkids