Controval
Product group

Instrumentation and analytics

Field instruments, analyzers and machinery protection for oil, gas, water and process plants. We supply them on their own, build them into skids and analyzer cabinets, and commission them.

At a glance

We supply, integrate and commission the instruments that tell you what your process and machines are doing.

  • Transmitters for pressure, temperature, flow and level, plus wireless and handheld devices
  • Liquid and gas analyzers with sample handling, in cabinets we design and build
  • Vibration, displacement and speed monitoring, including TSI systems
  • Installation, commissioning and spares support
01

Field devices and transmitters

Field transmitters turn a process variable into a signal your control system can use. They are the base of every control loop and safety system, so accuracy, stability and the right materials matter more than the headline price.

Request a quote
Wireless transmitters on a gas line

Pressure

A sensing element, usually a diaphragm, deflects with pressure and the transmitter outputs a signal. Choose gauge, absolute or differential, and the right range, wetted material and remote seals for corrosive or viscous fluids. A range that is too wide costs accuracy.

Temperature

An RTD or a thermocouple senses temperature, and a head or rail transmitter converts it to a standard signal. RTDs are more accurate and stable below about 500 C. Thermocouples cover higher temperatures and respond faster. A thermowell protects the sensor but slows response.

Flow

A transmitter reads the sensor of a flow meter, or the differential pressure across an orifice or venturi, and sends flow to the control system. Selection follows the meter type and fluid. See flow measurement for the technologies.

Level

Transmitters for level use differential pressure, radar, guided wave or other principles, and output a level signal. The best choice depends on the fluid, vapor, foam and vessel. See level measurement for the technologies.

Wireless

Battery or solar powered transmitters send data over a wireless network and avoid long cable runs. They suit monitoring, remote points and retrofits. Update rates are slower than wired, so they are less suited to fast control loops. Controval has broad experience supplying and commissioning wireless instruments in the oil and gas market.

Handheld

Portable communicators configure, calibrate and diagnose smart transmitters in the field. They save time at commissioning and in maintenance. They must support the protocols your devices use, such as HART. Handheld test tools include multimeters, portable analyzers (pH, ORP and others) and protocol generators.

Loggers and recorders

Data loggers and recorders store process readings over time for trending, audits and troubleshooting.

PMI and test equipment

Positive material identification (PMI) equipment checks the alloy of a part or weld. We also supply test and measurement instruments.

  • Pressure and temperature on lines, vessels and skids
  • Flow and level signals for control and alarm
  • Remote or hard-to-wire points using wireless devices
  • Calibration and commissioning with handheld communicators
  • Variable, range and required accuracy
  • Fluid, process connection type and wetted material
  • Operating and design pressure and temperature
  • Output signal and protocol, such as 4-20 mA with HART
  • Hazardous area class and enclosure requirements

We help you specify ranges, materials and outputs, supply the transmitters, and mount them on skids and panels. Our engineers wire, configure and commission them, and we supply spares for your installed base.

BrandsYokogawa
02

Analytical instrumentation

Analyzers measure what is in a fluid, not just how much of it moves. They are used for process quality, emissions, safety and treatment. An analyzer is only as good as its sample, so sample handling and conditioning are part of the job.

Request a quote
Analyzer shelter with sample conditioning

Water: pH, ORP, conductivity, oxygen, chlorine, turbidity, silica

Sensors in flow cells or inline assemblies measure water quality and send it to an analyzer. They guard boiler feedwater, treatment and discharge. Sensors need cleaning and calibration, and silica and chlorine often use reagent-based or specialized analyzers. Pure and ultrapure water also include dissolved oxygen (ppb and ppm), sodium, hardness, fluorides, ammonia for steam boilers and hydrazine (Eliminox). Drinking water and wastewater also include free and residual chlorine, suspended and dissolved solids, phosphate, calcite hardness, fluoride, and differential pH and ORP.

Gas: hydrocarbons, H2S, CO2, oxygen, BTU, sulfur

Analyzers use methods such as infrared, tunable laser, electrochemical or paramagnetic cells, depending on the gas. They check gas quality, safety and combustion. The method must suit the gas mix, and a clean, conditioned sample is essential. Hydrocarbons run from C1 to C6, and total sulfur, NO, NO2, SO2 and zirconia oxygen are also covered. We supply on-site analyzers or traditional ones with sample transport.

Chromatography and spectrometry

A gas chromatograph separates a sample into its components and measures each. Spectrometers identify them by how they absorb or emit light. They give detailed composition but cost more and need skilled upkeep and carrier or calibration gases.

Sampling equipment

We select automatic and manual sampling equipment. Key points are the sampling point, sample handling and conservation, the fast loop and the sample conditioner.

  • Water quality in boilers, cooling and treatment plants
  • Gas quality for fuel gas, sales gas and flare
  • Hydrogen sulfide and oxygen monitoring for process and safety
  • Heating value and composition for fuel and custody transfer
  • Component to measure and range
  • Sample fluid, composition and contaminants such as water, solids or H2S
  • Sample pressure, temperature and distance from the tap to the analyzer
  • Response time and accuracy needed
  • Hazardous area class, utilities available and where the analyzer will sit

We select the analyzer and design the sample system, then build the analyzer cabinet or shelter ourselves. We commission it and supply sensors, consumables and spares.

BrandsKECOSICKThermo Scientific
03

Rotating equipment monitoring and protection

Pumps, compressors and turbines fail when something changes: vibration rises, the shaft moves, or speed drifts. Monitoring systems detect this early. Protection systems trip the machine before damage spreads.

Request a quote
Hydraulic valve actuator unit

Vibration

Accelerometers or velocity sensors on the casing, and proximity probes on the shaft, detect imbalance, misalignment and bearing wear. Casing sensors suit general machines. Shaft probes suit large machines with fluid film bearings.

Displacement

Non-contact proximity probes measure shaft position, thrust and the distance to a surface. They show axial and radial movement, and are used for thrust protection and eccentricity. They need a clean target and correct gap setting.

Speed

Magnetic pickups or proximity probes read a toothed wheel or keyway to give rotational speed. It feeds speed control and overspeed trip. Zero-speed and keyphasor signals help with other measurements.

TSI

A turbine supervisory instrumentation system combines vibration, shaft position, speed and temperature on a turbine. It shows its condition during start-up and operation and trips it on alarm limits. Racks and cabling must follow the machine's protection philosophy.

  • Vibration monitoring on pumps, motors, fans and compressors
  • Shaft position and thrust on turbines and compressors
  • Speed measurement and overspeed protection
  • Turbine supervisory systems for steam and gas turbines
  • Machine type, speed and bearing type
  • Measurements needed: vibration, position, speed or temperature
  • Alarm and trip requirements
  • Existing monitoring system, if any, and its brand
  • Hazardous area class and distance to the control room

We help you choose sensors and monitors for your machine class, then design, build and commission the monitoring panels and wiring. We also supply spares for what you already have installed.

FAQ

Common questions

Do you also supply the sample system for an analyzer?

Yes. We design the sample handling and conditioning and build it with the analyzer in a cabinet or shelter. A poor sample is the most common reason an analyzer reads wrong.

Can you replace transmitters we already have installed?

Yes. Send us the tag, model or datasheet. We will propose a compatible replacement or an upgrade, and supply spares for your installed base.

What is the difference between vibration monitoring and a protection system?

Monitoring shows trends and warns you early. Protection acts: it trips the machine on limits. Critical machines often need both, wired to the control or safety system.

Can you commission what you supply?

Yes. Our engineers install, wire, calibrate and commission instruments, analyzers and monitoring panels, in the shop or on site.

Looking for a complete system?

See how we integrate these products into skids, built and tested in our workshops.